KR600 TRANSFORMER TO SERIES CIRCUIT
Low leakage inductance for improved powerline communication
KR600 series design provides very low leakage inductance. It supports single lamp control and other advanced control and monitoring equipments. KR600 is the most energy efficient transformer in the market due to 360-degree wound toroidal core design. Transformers are Intertek certified to FAA AC and approved by IEC. They also comply with ICAO Annex 14 and several other national standards (MAK, CAAC).
- Superior isolation resistance by thermoplastic elastomer (TPE)
- Optimal physical size and electrical performance of toroidal structure
- Rated power 10 – 500 W
- Rated current 6.6 A/6.6 A , other currents upon request
- Power factor > 0.97
- L (leak) 20µH - 130 µH
- L (magn) 13.0mH - 64 mH
KR600 is used to supply the current in the AGL series circuit and to provide a separation point between the primary and secondary circuits. Thermoplastic elastomer (TPE) encapsulated KR600 series transformers are designed in toroidal shape, which provides superior electrical performance. Toroidal is a symmetric “donut” shape which ensures the lowest leakage inductance. It also supports single lamp control and more advanced control and monitoring requirements.
KR600 is the most energy efficient transformer on the market. Transformers are Intertek certified to FAA AC andapproved by IEC. They also comply with ICAO Annex 14 and several other national standards (CAAC, MAK).
• Superior isolation resistance by thermoplastic elastomer (TPE)
• Optimal physical size and electrical performance of toroidal structure
o Rated power 10–500 W
o Rated current 6.6 A/6.6 A , other currents upon request.
o Power factor > 0.97
o L (leak) 20 µH–130 µH
o L (magn) 13.0 mH–64 mH
Connections
Standard KR600 series
Primary leads Primary connector type Secondary lead Secondary connector type 2 x 60 cm/1.969 ft, 1 x 6 mm²
FAA L-823 Style 2 Plug & Style 9 Receptacle
1 x 1.2 m/3.937 ft, 2 x 2.5 mm2
FAA-L-823 Style 8
KR600 with or without earthing (grounding)
EFLA supplies transformers with or without earthing. The earthing is connected to the end of the secondary winding on the side of the larger socket. This means that the bigger socket of the secondary side is grounded.